Why your Trane Heating & Cooling inverter shuts down during morning dew or heavy rain, and how to safely inspect the DC ground fault.
Under US electrical standards (NEC 690.41 and UL 1741), all grid-tied solar inverters must measure the DC electrical resistance between the positive/negative solar conductors and Earth ground prior to connecting to the utility grid. If this resistance falls below 600 kΩ (or 1 MΩ on commercial units), the inverter immediately halts power generation and locks out with 4 Red Flashes to prevent roof fires and equipment destruction.
Moisture is conductive. A micro-crack in a solar panel backsheet, an unsealed MC4 quick-connector, or a wire pinched beneath a mounting bracket will only trigger an isolation fault when morning condensation, dew, or rainfall creates a conductive bridge to the aluminum rail.