Why your Generac Power Systems inverter shuts down during morning dew or heavy rain, and how to safely inspect the DC ground fault.
Under US electrical standards (NEC 690.41 and UL 1741), all grid-tied solar inverters must measure the DC electrical resistance between the positive/negative solar conductors and Earth ground prior to connecting to the utility grid. If this resistance falls below 600 kΩ (or 1 MΩ on commercial units), the inverter immediately halts power generation and locks out with Error 1902 to prevent roof fires and equipment destruction.
Moisture is conductive. A micro-crack in a solar panel backsheet, an unsealed MC4 quick-connector, or a wire pinched beneath a mounting bracket will only trigger an isolation fault when morning condensation, dew, or rainfall creates a conductive bridge to the aluminum rail.
Generac Power Systems ground faults require roof access and high-voltage test equipment. Connect with certified local contractors.